Underground Tank Monitoring

Near-real-time monitoring of underground storage tanks via direct ATG connection — prevent runouts, ensure compliance, and optimize fuel deliveries.

Near-real-time fill percentage, volume, and ullage for every underground tank

Product temperature monitoring for accurate net volume calculations

Water level detection for early identification of tank integrity issues

Threshold-based alerts when business rules are breached

Environmental compliance data — leak tests, alarm history, and scheduled compliance reports

Two connectivity options: cellular gateway (RS-232) or hardware-less IP/VPN

Compatible with Veeder-Root, Franklin Fueling, OPW, and any VR-command-compatible ATG

Deep Integration with ATGs

Underground Storage Tanks (USTs) are the backbone of convenience store and fuel retail operations. Kii’s underground tank monitoring capability connects directly to the Automated Tank Gauge (ATG) console at each site, extracting the full range of data that the console captures — and making it accessible in near-real-time from anywhere.

Unlike solutions that only read basic level data, Kii pulls the complete data set from the ATG: fuel levels, ullage, water levels, temperature, leak test results, alarm history, and environmental compliance status. This is the same data that would require a site visit or a call to the station to obtain manually.

ATG Compatibility

Kii supports a wide range of ATGs — from legacy systems dating back to the early 1990s using the TLS-250-compatible protocol through current-generation hardware.

Supported Vendors

  • Veeder-Root — the most widely deployed ATGs in the US petroleum market
  • Franklin Fueling Systems, including INCON consoles
  • OPW, including legacy EECO System consoles
  • Any other ATG vendor whose equipment implements the Veeder-Root command protocol, which has become the de facto industry standard

See ATG compatibility in detail →

Platform Capabilities

The Kii platform extracts the complete data set available from connected ATGs, including:

  • Tank inventory levels and volume calculations
  • Environmental compliance reports and leak test results
  • Alarm history and sensor status

The specific data available depends on the ATG model and its installed sensors. All ATGs connect via RS-232 serial or IP/VPN.

Connectivity Options

Cellular Gateway

For sites without existing IP network infrastructure, the CAT 4 Cellular Gateway connects to the RS-232 port on the ATG and transmits data over cellular. Installation takes approximately 10 minutes and requires no specialized training. The gateway is powered by a standard AC outlet and begins transmitting data immediately upon connection.

This is the preferred option for independent operators, small to mid-size chains, and any location where deploying network infrastructure is impractical or cost-prohibitive.

Hardware-Less IP/VPN

For operators with existing IP connectivity at their sites, Kii connects directly to ATGs over a secure VPN — eliminating per-site hardware entirely. The Kii platform communicates with the ATG over IP, pulling the same complete data set as the gateway option.

This approach is ideal for large-scale deployments where eliminating hardware reduces cost and accelerates rollout. Kii works closely with the customer’s IT team to establish and maintain the VPN connectivity.

What Gets Monitored

What an underground tank system reportsCross-section of a fueling site: the ATG console on the store wall, a double-walled underground tank with fuel and water, the probe that measures them, the interstitial space between the walls, the tank sump holding the head of the submersible pump and its line leak detector, the pump itself near the bottom of the tank, the product line, and the sump under the dispenser island.ATG consoleUllageFuelDispenserProbeLevel, temperature,and waterWaterInterstitial space and sensorLine leak detectorTank sump sensorDispenser sump sensor
Orange marks the points the ATG measures and Kii monitors: the probe and its floats, the interstitial space, the sumps, and the product line.
ParameterDescription
Fill LevelCurrent volume and percentage for each tank
UllageAvailable capacity for delivery planning
Product TemperatureFor net volume calculations and quality monitoring
Water LevelEarly detection of water intrusion or tank integrity issues
Tank StatusCurrent health indicators and warnings
Average Daily Usage7-day and 30-day consumption patterns (ADU7, ADU30)
Pre-Fill LevelsInventory tracking before and after deliveries
Leak Test ResultsPressure line, volumetric, and in-tank test data
Alarm HistoryComplete log of all alarms with timestamps
Compliance StatusEnvironmental compliance summary per site

Frequently Asked Questions

Which tank gauges does Kii support?

Veeder-Root, Franklin Fueling, OPW, and any automatic tank gauge that implements the Veeder-Root command set, from early-1990s consoles through current-generation hardware. See ATG Compatibility.

How does Kii connect to the gauge?

Either through a cellular gateway on the gauge’s RS-232 serial port, which needs no site network or IT involvement, or directly over the customer’s existing network, with no hardware at each site.

What data does Kii collect from an underground tank system?

Fill level, ullage, product temperature, and water level for every tank, plus deliveries, alarms, leak test results, and the status of sump and interstitial sensors. The data available depends on the gauge model and its installed sensors.

Can environmental compliance reports be scheduled?

Yes. Reports can be delivered daily, weekly, or monthly, and every report is also available on demand.

Is the tank gauge exposed to the internet?

No. Kii never exposes an automatic tank gauge to the public internet, and the platform sends gauges only read-only requests from a fixed allowlist. See Security & Compliance.

Underground Tank Monitoring interface screenshot

Ready to Get Started?

See how Underground Tank Monitoring can transform operations.